Plating Offset (YPI)

The Plating Offset (YPI) tab only appears for ADF machines.

YPI

Index (Plating) D = direct value in Sintral

Insert Position <<

Offset of the yarn carrier with stroke to the left

Horizontal panning of the insertion position (x)

  • Positive value: Following basic yarn.
    The thread is inserted in the needles later on.
    Default: 6.5 mm
  • Negative value: Leading plating yarn
    Default: 0 mm

Value range: -100.0 to 100.0 mm
Step width: 0.1 mm

Height <<

Offset in the height of the yarn carrier with stroke to the left

Panning in height (y)
Corrects the insertion angle

  • Positive value: Steeper yarn angle
    Default: 0.9 mm for the following basic yarn
  • Negative value: Flatter yarn angle

Value range: -2.0 to 5.0 mm
Step width: 0.1 mm

Insert Position >>

Offset of the yarn carrier with stroke to the right

Horizontal panning of the insertion position (x)

  • Positive value: Following basic yarn.
    The thread is inserted in the needles later on.
    Default: 6.5 mm
  • Negative value: Leading plating yarn
    Default: 0 mm

Value range: -100.0 to 100.0 mm
Step width: 0.1 mm

Height >>

Offset in the height of the yarn carrier with stroke to the right.

Panning in height (y)
Corrects the insertion angle

  • Positive value: Steeper yarn angle
    Default: 0.9 mm for the following basic yarn
  • Negative value: Flatter yarn angle

Value range: -2.0 to 5.0 mm
Step width: 0.1 mm

Description

Note on the use of the entry. You can enter a text here.