Sıra raportu
|
Defines an area in the pattern that can be repeated as required using the value of the corresponding factor.
|
|
Anahtarlanabilir raport (fonksiyon)
|
If the value of the parameter specified in the RS column is contained in the value range specified in the columns Min and Max, then the cycle is carried out once. This switch is used with the modules supplied by Stoll for the comb starts in the Starts/Stoll module group. Here, for example, a switch is installed that determines whether or not the comb is to be used. For example, Sintral has the following appearance:
IF RS17 = 0 F:SCHALTER-1; C Kamm ein/aus IF #137 = 20 F:SCHALTER-4; C Zus.Anfangsr.E20
|
|
Alternatif açılmış sıra
|
If the parameter specified in the RS column is within the value range specified in the Min and Max columns, then the instruction is not carried out in this system. This cycle is an empty row. This is not carried out when RS 19 = 1. As with the cycle counter RS 19 the use of the elastic yarn is activated and deactivated, this means that no empty row is carried out when the elastic yarn is used. On the other hand, an empty row is carried out when the elastic yarn is not used. This is necessary, as otherwise the carriage would be on the wrong side. This cycle is inserted by Technical Processing when a comb start with elastic yarn and with an RR transition has been selected. It is used in conjunction with the cycle Individual switchable row for clamping. The related Sintral lines are, for example:
SBEG Y-1B:F1B; IF RS19=1 Y-1B:C; V0 S1 IF RS19<>1 V0 S0 SEND
|
|
Ayrı ayrı ayarlanabilen sıra
|
If the parameter specified in the RS column is within the value range specified in the Min and Max columns, then the instruction is carried out, otherwise it is not. The difference to the switchable cycle lies in the fact that this cycle is allocated to a single system. With this cycle the elastic yarn is clamped. This is carried out when RS 19 = 1. As with the cycle counter RS 19 the use of the elastic yarn is activated and deactivated, this means that the elastic yarn is clamped when it is used in the pattern. In the process the clamping of elastic thread is carried out in System 1 and the transfer rows that follow in the pattern in System 2. If the RS for the elastic thread is now switched off, then the system for clamping is also switched off. However, the transfer row in System 2 from this stroke is retained. This cycle is inserted by Technical Processing when a comb start with elastic yarn and with a loose row has been selected as a transition. The related Sintral lines are, for example:
SBEG Y-1B:F1B; IF RS19=1 Y-1B:C; V0 S1 >> S:<1->UVS+; S2 WMF4 SEND
|
|
Bekleme kuyruğu
|
The cycle is carried out until the value from the RS column has reached the value range in the columns Min and Max. This switch is used with the modules supplied by Stoll for knitting-in of the comb thread in the Technical/Comb thread module group. In the process it is ensured that the comb is in its home position before it moves upward after knitting-in the comb thread. For example, Sintral has the following appearance:
IF #140 = 1 F:SCHALTER-3; GOTO #123 C Kamm in END
|