Additional columns for CMS T machines

Additional columns are available for CMS T machines where you make the following settings:

<> VZVK

Direction of the racking correction of the front additional bed

VZVK

Racking correction of the front additional bed
Value range: 0 to 10

VVZV

Racking speed of the front additional bed
Value range: 1 to 32
Not specified: VVZV=32

VZV +/-

Overracking of the front additional bed
Value range: -24 to -1 and 1 to 24
Step width : 1/8 of the needle distance

  • V+n racking moves further in the selected direction by the value n and then into the racking position.
  • V-n racking moves by the value n in the opposite direction and then in racking position.

<> VZ^K

Direction of the racking correction of the rear additional bed

VZ^K

Racking correction of the rear additional bed

Value range: 0 to 10

VV^V

Racking speed of the rear additional bed

Value range: 1 to 32
Not specified: VV^V=32

VZ^ +/-

Overracking of the rear additional bed

Value range: -24 to -1 and 1 to 24
Step width : 1/8 of the needle distance

  • V+n racking moves further in the selected direction by the value n and then into the racking position.
  • V-n racking moves by the value n in the opposite direction and then in racking position.