Table entries (main take-down)
Make the following settings in this table:
|
ID |
Sorts the index column |
|
|
Shows the selection for the needle bed. Take additional values, even of different tables, to the cursor by CTRL. |
|
WMF/WBF |
Index (Main Take-down function) D = direct value in Sintral |
|
Color |
Index Color
Click the color to change the color value. |
|
|
Default Entry |
|
WM(N) |
WMN: Modify the fabric take-down value dependent on the fabric width in accordance with the quantity of needles. WM: No dependency on the fabric width. |
|
WM |
Fabric take-down value |
|
WM min |
Fabric take-down value for minimum fabric width |
|
WM max |
Fabric take-down value for maximum fabric width |
|
N min |
Quantity of needles for minimum fabric width |
|
N max |
Quantity of needles for maximum fabric width |
|
WMI |
Fabric take-down impulse value: Default = 3 |
|
WM^ |
Number of degrees for the reverse rotation of the take-down |
|
WMC |
Value for the sensitivity of the stop motion control of the main take-down: 0 = no stop motion 1 = insensitive 32= very sensitive |
|
WM+C |
Quantity of knitting rows for the fabric take-down blocking control: 0 = no supervision |
|
WMK+C |
Quantity of knitting rows for the comb monitoring: 0 = no supervision |
|
Action |
Belt Take-down Action
|
|
Value |
Belt Take-down Value: WB=0..30, WB^=1..3 |
|
Description |
Note on the use of the entry. You can enter a text here. |
.