Table Entries (Main Take-down)
Make the following settings in this table:
|
ID |
Sorts the index column |
|
|
Show or hide pattern-related values
In the context menu of a selected row you can insert a row for pattern-related values of a specific pattern. |
|
|
Shows the selection for the needle bed. Take additional values, even of different tables, to the cursor by CTRL. |
|
WMF/WBF |
Index (Main Take-down function) D = direct value in Sintral |
|
Pattern |
Name of the pattern in case of rows with pattern-related values |
|
Color |
Index Color
Click the color to change the color value. |
|
|
STOLL Template |
|
WM(N) |
WMN: Modify the fabric take-down value dependent on the fabric width in accordance with the quantity of needles. WM: No dependency on the fabric width. |
|
WM |
Fabric take-down value |
|
WM min |
Fabric take-down value for minimum width of pattern Value range: 0 - 31.5 (Useful with Fully Fashion) |
|
WM max |
Fabric take-down value for maximum width of pattern Value range: 0 - 31.5 (Useful with Fully Fashion) |
|
N min |
Quantity of needles for minimum fabric width (Useful with Fully Fashion) |
|
N max |
Quantity of needles for maximum fabric width (Useful with Fully Fashion) |
|
WMI |
Fabric take-down impulse value: Default = 3 The fabric take-down impulse causes a pre-tensioning of the take-down in the carriage reversal. The WMI value determines the strength of the pre-tensioning. Value range: 0 - 15 |
|
WM^ |
Number of degrees for the reverse rotation of the take-down The brake of the active take-down system (main take-down or comb take-down) is opened for a maximum of 2.5 seconds. Value range: If either of both the conditions is fulfilled, then the brake is closed again. |
|
WMC |
Value for the sensitivity of the stop motion control of the main take-down: 0 = no stop motion 1 = insensitive 32= very sensitive Set the speed control of the active take-down system (main take-down or comb take-down) to the value n (0-32). If the take-down system turns too quickly, the machine is stopped. Value range: 0 - 32 |
|
WM+C |
Quantity of knitting rows for the fabric take-down blocking control: 0 = no supervision Monitoring of main take-down. If the take-down has not turned after n (0-100) knitting rows, the machine will stop. Value range: 0 - 100 |
|
WMK+C |
Quantity of knitting rows for the comb monitoring: 0 = no supervision Monitoring of the comb. If the comb has not moved after n (0-100) knitting rows, the machine will stop. Value range: 0 - 100 |
|
Description |
Note on the use of the entry. You can enter a text here. |
.