Fabric take-down table
Display the fabric take-down table:
- 1
- Call-up the / menu.
- or -
Press the Fabric take-down table button in the Global pattern parameters dialog box.
Each line within the table is referred to as an entry. Each entry is represented with a color and contains the fabric take-down values. The following columns are contained in the fabric take-down table:
|
Column |
Value |
Meaning |
|---|---|---|
|
|
Consecutive numbering of entries | |
|
Color of entry | ||
|
WM(N) |
WMN |
Modify the fabric take-down value dependent on the fabric width in accordance with the quantity of needles. |
|
WM |
Do not consider number of needles | |
|
WMF |
1-50 |
Index for indirect allocation of the fabric take-down value |
|
WM |
0-31,5 |
Fabric take-down value when this is not changed in accordance with the number of needles. |
|
WM min |
0-31,5 |
Fabric take-down value for minimum fabric width |
|
WM max |
0-31,5 |
Fabric take-down value for maximum fabric width |
|
N min |
0-1727 |
Quantity of needles for minimum fabric width |
|
N max |
0-1727 |
Quantity of needles for maximum fabric width |
|
WMI |
0-15 |
Fabric take-down impulse value |
|
WM^ |
0-120° |
Number of degrees for the reverse rotation of the take-down |
|
WMC |
0-32 |
Value for the sensitivity of the stop motion control of the main take-down
|
|
WM+C |
0-100 |
System number for the fabric take-down blocking control
|
|
WMK+C |
0-100 |
System number for the comb monitoring
|
|
Name for the entry | ||
|
Status of the entry | ||
Values for functions that are not present for the specified machine are nevertheless written to the knitting program (Sintral) or to the setup file. These values are ignored by the machine.