Fabric take-down table

Display the fabric take-down table:

    1
    Call-up the Pattern Parameters / Fabric take-down menu.
    -  or  -
    Press the Fabric take-down table button in the Global pattern parameters dialog box.

Each line within the table is referred to as an entry. Each entry is represented with a color and contains the fabric take-down values. The following columns are contained in the fabric take-down table:

Column

Value

Meaning

No.

 

Consecutive numbering of entries

Color

Color of entry

WM(N)

WMN

Modify the fabric take-down value dependent on the fabric width in accordance with the quantity of needles.

WM

Do not consider number of needles

WMF

1-50

Index for indirect allocation of the fabric take-down value

WM

0-31,5

Fabric take-down value when this is not changed in accordance with the number of needles.

WM min

0-31,5

Fabric take-down value for minimum fabric width

WM max

0-31,5

Fabric take-down value for maximum fabric width

N min

0-1727

Quantity of needles for minimum fabric width

N max

0-1727

Quantity of needles for maximum fabric width

WMI

0-15

Fabric take-down impulse value
Default = 3

WM^

0-120°

Number of degrees for the reverse rotation of the take-down

WMC

0-32

Value for the sensitivity of the stop motion control of the main take-down

  • 0= no stop motion
  • 1= insensitive
  • 32= very sensitive

WM+C

0-100

System number for the fabric take-down blocking control

  • 0= no supervision

WMK+C

0-100

System number for the comb monitoring

  • 0= no supervision

Description

Name for the entry

F, U, M, S, G (status columns)

Status of the entry

Values for functions that are not present for the specified machine are nevertheless written to the knitting program (Sintral) or to the setup file. These values are ignored by the machine.

When you remain briefly over the header of the respective column with the mouse pointer, you receive additional information for some columns on which entry is concerned in this column.