Sintral command DEVOUT
|
Syntax: | Devout(1,2,3,4,5,6,7,8); |
Parameter 1-8: | Integer 16 Bit |
|
Parameter | Function | Comment |
1 | Device (1 = Feed wheel EFS) |
|
2 | 0 = Initializing | Must be executed before START. |
1 = Working thread tension | Does not need to be activated. | |
2 = Reciprocation tension (with returning) On/Off | Must be activated with each change of the reciprocation tension | |
3 = Reciprocation tension |
| |
4 = Yarn tension reduction On/Off | Must be activated only once after the start. | |
5 = Yarn tension reduction |
| |
6 = Winding number | Is effective only after SP1 and new threading-up of the EFS | |
100 = Calibrating |
| |
3 | Address / Group 0= all 1= Group 1 2= Group 2 3= Group 3 4= Group 4 5= Group 5 6= Group 6
| Group 0 is only used for initialization and calibration Otherwise, the group is to be addressed with the command.
|
4 | Value (see the Parameter 2 function) Working thread tension by N/mm 0= Off / 1= On Reciprocation tension by N/mm 0= Off / 1= On Yarn tension reduction by N/mm |
|
5 |
|
|
6 |
|
|
7 |
|
|
8 |
|
|
|
Initialize | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Initialize with a predefined yarn tension | |||||||||
Meaning | Parameter | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Devout | Device | Function | Group | Value |
|
| |||
Sintral | EFS | INIT | --- | Yarn tension- |
| ||||
Reduction | Working | Reciprocation | - | - | |||||
1 | 0 | 0 | v | v | v | 0 | 0 | ||
v = 5-400 (corresponds to 0.5 cN - 40,0 cN) | |||||||||
Syntax: | DEVOUT(1,0,0,v,v,v,0,0); | ||||||||
Example: | DEVOUT(1,0,0,60,50,70,0,0); | ||||||||
This command must be executed by all means after switching on the machine to establish the communication with the EFS devices properly.
Therefore, start always with SP1 after switching on.
When initializing, values for the yarn tension are specified
Without a specification of values, the yarn tension would collapse to 0.5 cN. The specification of a start value prevents the yarn tension from collapsing briefly when starting with SP1.
|
Calibrating: | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Calibrating sensor | |||||||||
Meaning | Parameter | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Devout | Device | Function | Group | Value |
|
| |||
Sintral | EFS | CAL | --- | Yarn tension- |
| ||||
Reduction | Working | Reciprocation | - | - | |||||
1 | 100 | 0 | 0 | 0 | 0 | 0 | 0 | ||
When this command is executed, the EFS device must be inactive for at least 1 second. | |||||||||
Syntax: | DEVOUT(1,100,0,0,0,0,0,0); | ||||||||
Example: | DEVOUT(1,100,0,0,0,0,0,0); | ||||||||
|
Working yarn tension | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Meaning | Parameter | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Devout | Device | Function | Group | Value |
|
|
|
| |
Sintral | EFS | FS | 0-6 | Yarn tension |
| ||||
1 | 1 | n | v | 0 | 0 | 0 | 0 | ||
n = 0 for all groups (should not be used) n = 1 – 6 for corresponding group (the group is defined with mode 1 at the EFS device) v = 5-400 (corresponds to 0.5 cN - 40,0 cN) | |||||||||
Syntax: | DEVOUT(1,1,n,v,0,0,0,0); | ||||||||
Example: | DEVOUT(1,1,1,50,0,0,0,0); | ||||||||
|
Reciprocation tension On/Off (with returning) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Meaning | Parameter | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Devout | Device | Function | Group | Value |
|
|
|
| |
Sintral | EFS | RFS ON/OFF | 0-6 | ON/OFF |
| ||||
1 | 2 | n | v | 0 | 0 | 0 | 0 | ||
n = 0 for all groups (can be used for this function) n = 1 – 6 for corresponding group (the group is defined with mode 1 at the EFS device) v 0=OFF / 1= ON | |||||||||
Syntax: | DEVOUT(1,2,n,v,0,0,0,0); | ||||||||
Example: | DEVOUT(1,2,1,1,0,0,0,0); | ||||||||
In case of a change of the yarn tension in the reciprocation mode, the reciprocation tension must always be activated previously.
I.e. the two commands are always indicated together in this order:100 DEVOUT(1,2,1,1,0,0,0,0); C Reciprocation tension ON101 DEVOUT(1,3,1,70,0,0,0,0); C With group 1 the reciprocation tension is set to 7 cN
|
Reciprocation tension (with returning) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Meaning | Parameter | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Devout | Device | Function | Group | Value |
|
|
|
| |
Sintral | EFS | RFS | 0-6 | Yarn tension |
| ||||
1 | 3 | n | v | 0 | 0 | 0 | 0 | ||
n = 0 for all groups (can be used for this function) n = 1 – 6 for corresponding group (the group is defined with mode 1 at the EFS device) v = 5-400 (corresponds to 0.5 cN - 40,0 cN) | |||||||||
Syntax: | DEVOUT(1,3,n,v,0,0,0,0); | ||||||||
Example: | DEVOUT(1,3,1,70,0,0,0,0); | ||||||||
|
Yarn tension reduction On/Off (reduced yarn tension) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Meaning | Parameter | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Devout | Device | Function | Group | Value |
|
|
|
| |
Sintral | EFS | REDFS ON/OFF | 0-6 | ON/OFF |
| ||||
1 | 4 | n | v | 0 | 0 | 0 | 0 | ||
n = 0 for all groups (can be used for this function) n = 1 – 6 for corresponding group (the group is defined with mode 1 at the EFS device) v 0=OFF / 1= ON | |||||||||
Syntax: | DEVOUT(1,4,n,v,0,0,0,0); | ||||||||
Example: | DEVOUT(1,4,1,1,0,0,0,0); | ||||||||
|
Yarn tension reduction (reduced yarn tension) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Meaning | Parameter | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Devout | Device | Function | Group | Value |
|
|
|
| |
Sintral | EFS | REDFS | 0-6 | Yarn tension |
| ||||
1 | 5 | n | v | 0 | 0 | 0 | 0 | ||
n = 0 for all groups (can be used for this function) n = 1 – 6 for corresponding group (the group is defined with mode 1 at the EFS device) v = 5-400 (corresponds to 0.5 cN - 40,0 cN) | |||||||||
Syntax: | DEVOUT(1,5,n,v,0,0,0,0); | ||||||||
Example: | DEVOUT(1,5,1,60,0,0,0,0); | ||||||||
|
Number of yarn windings | |||||||||
|---|---|---|---|---|---|---|---|---|---|
Meaning | Parameter | 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 |
Devout | Device | Function | Group | Value |
|
|
|
| |
Sintral | EFS | WANZ | 0-6 | Yarn tension |
| ||||
1 | 6 | n | v | 0 | 0 | 0 | 0 | ||
n = 0 for all groups (can be used for this function) n = 1 – 6 for corresponding group (the group is defined with mode 1 at the EFS device) v = 1-40 Number of windings | |||||||||
Syntax: | DEVOUT(1,6,n,v,0,0,0,0); | ||||||||
Example: | DEVOUT(1,6,1,7,0,0,0,0); | ||||||||
The EFS device must be unthreaded. After reading the DEVOUT data, the windings are redefined.