CMS ADF - Setup2, extension in the "YC/YCI" tab

In the YC/YCI tab, four columns were added (Setup2 Editor -> Yarn carrier menu -> YC/YCI)

new

Explanation

Value range

^ +/-[mm]

Correction of the High position of the yarn carrier (ADF)

Default: 0 mm

Minimum value: -2.0
Maximum value: 5.0
Step width: 0.1 mm

v +/-[mm]

Correction of the Deep position of the yarn carrier (ADF)

Default: 0 mm

Minimum value: -2.0
Maximum value: 5.0
Step width: 0.1 mm

A-MSEC

Speed of the yarn carrier with a system independent, autarkic yarn carrier run.

Default: 2.0 meters/second

Minimum value: 0.05
Maximum value: 2.0
Step width: 0.05

F

Activate or deactivate Automatic tracking of the yarn carriers when widening.

If the distance between the yarn carrier and the fabric selvedge is too small, then the yarn carriers will be moved automatically following the fabric selvedge.

Activate Automatic tracking (standard setting)

Deactivate Automatic tracking