Working with the Speed (MSEC) tab
I. Open Speed (MSEC) tool window and select / change an entry:
Design Pattern is selected.- The
Speed (MSEC) control column is displayed.
- 1
- Open the selection list in the Home ribbon at
Tool Windows
and select
Pattern Parameters
.
- or -
click the
Pattern Parameters
icon directly under Parameter. - The Pattern Parameters
tool window appears.

- 2
- Select the
Speed (MSEC) section. - 3
- Default tab
- or -
Select User . - 4
- Select the desired speed value in the
column and enter it in the control column.
- The default setting will be overwritten in these design rows.
Options in the toolbar
|
| Selecting the default value to enter in the control column |
| Deleting an entry in the control column |
| Show Pattern-related Values |
| Hide Pattern-related Values |
Column labels of the Speed (MSEC) tool window
|
Column | Display |
|---|---|
ID / IDv / ID^ | Consecutive numbering and sorting of the entries |
| Selecting the speed value to enter it in the control column |
MSEC | Index for indirect allocation of the speed |
Color | Display of colors to enter in the control columns |
m/s | Value for the speed |
|
Column |
Display | |
|---|---|---|
|
Description |
Comment on the use of the entry. | |
|
* |
|
Entry is not defined as favorite, meaning the entry is only within the Default table available. |
|
|
Entry is defined as favorite, meaning the entry is available within the User table or directly via the context menu of the control columns. | |
|
O |
|
Value cannot be overwritten (Overwrite) by a value of another table. |
|
|
Value can be overwritten (Overwrite) by a value of another table. (Standard) | |
|
|
|
The entry will not be applied to the Setup data
|
|
|
The entry will be applied to the Setup data.
| |
|
G |
|
All settings of the Default or User
table are STOLL defaults (STOLL Template).
|
|
|
These settings of the Default or User
table are now User Standards (User-Template)
| |
II. Specify favorites:
Design Pattern is selected.
- 1
- Open the Pattern Parameters tool window.
- 2
- Select the
Speed (MSEC) section. - 3
- Select the Default tab.
- 4
- Mark the desired entry in the * column
. - 5
- Close the tool window with
.
- The selected entry will be displayed in the context menu and can be inserted in the design pattern for the speed.
III. Add a new entry in the speed (MSEC) tab:
New entries can only be added in the User tab.
Design Pattern document window is selected.
- 1
- Open the Pattern Parameters tool window.
- 2
- Select the
Speed (MSEC) section. - 3
- Select the User tab.
- 4
- Set the cursor in the left table column to the row.
- 5
- Call up the Add Table Row... context menu.
- A new entry will be added at the end of the table.
- 6
- Make the desired specifications in the columns of the new entry.
- 7
- Close the table with
.
- Changes are saved to the table and are available in the project for each order and for all of its individual patterns.
The changes will be saved to the *.spf file when saving the project.
IV. Apply entry of the Speed (MSEC) tab to the pattern:
- The Design Pattern
document window is selected. - The
Speed (MSEC) control column is displayed.
- 1
- Open the Pattern Parameters tool window.
- 2
- Select the
Speed (MSEC) section. - 3
- Select the User tab.
- 4
- Select the desired speed value in the
column. - 5
- Enter the selected speed value in the control column.
More optional control columns:
-
Machine Slow (ML) -
Machine Stop (MS)



: All entries used in the pattern are applied by default to the Setup data.