Table entries (main take-down)

Make the following settings in this table:

ID

Sorts the index column

Shows the selection for the needle bed. Take additional values, even of different tables, to the cursor by CTRL.

WMF/WBF

Index (Main Take-down function) D = direct value in Sintral

Color

Index Color Click the color to change the color value.
Colors in use are marked by .

STOLL Template

WM(N)

WMN: Modify the fabric take-down value dependent on the fabric width in accordance with the quantity of needles. WM: No dependency on the fabric width.

WM

Fabric take-down value

WM min

Fabric take-down value for minimum fabric width

Value range: 0 - 31.5

(Useful with Fully Fashion)

If the entry is changed manually, the following marking appears beside the entry.
The technical processing will not change this entry.

WM max

Fabric take-down value for maximum fabric width

Value range: 0 - 31.5

(Useful with Fully Fashion)

If the entry is changed manually, the following marking appears beside the entry.
The technical processing will not change this entry.

N min

Quantity of needles for minimum fabric width

(Useful with Fully Fashion)

If the entry is changed manually, the following marking appears beside the entry.
The technical processing will not change this entry.

N max

Quantity of needles for maximum fabric width

(Useful with Fully Fashion)

If the entry is changed manually, the following marking appears beside the entry.
The technical processing will not change this entry.

WMI

Fabric take-down impulse value: Default = 3

The fabric take-down impulse causes a pre-tensioning of the take-down in the carriage reversal. The WMI value determines the strength of the pre-tensioning.

Value range: 0 - 15

WM^

Number of degrees for the reverse rotation of the take-down

The brake of the active take-down system (main take-down or comb take-down) is opened for a maximum of 2.5 seconds.
The take-down roller or the comb take-down turn back by a maximum number of the indicated degrees (depending on the fabric tension and the fabric take-down value).

Value range:
CMS 5xx, 7xx, 8xx, ADF: 9-60 degrees
CMS 9xx: 9-120 degrees

If either of both the conditions is fulfilled, then the brake is closed again.
The fabric take-down value (n=0-31.5) becomes active again at the carriage return.

WMC

Value for the sensitivity of the stop motion control of the main take-down: 0 = no stop motion 1 = insensitive 32= very sensitive

Set the speed control of the active take-down system (main take-down or comb take-down) to the value n (0-32). If the take-down system turns too quickly, the machine is stopped.

Value range: 0 - 32

WM+C

Quantity of knitting rows for the fabric take-down blocking control: 0 = no supervision

Monitoring of main take-down. If the take-down has not turned after n (0-100) knitting rows, the machine will stop.

Value range: 0 - 100

WMK+C

Quantity of knitting rows for the comb monitoring: 0 = no supervision

Monitoring of the comb. If the comb has not moved after n (0-100) knitting rows, the machine will stop.

Value range: 0 - 100

Description

Note on the use of the entry. You can enter a text here.