Global Pattern Parameters...

The global pattern parameters are values specified for the pattern parameters that are used when generating new patterns. The global pattern parameters can be changed via the Global pattern parameters... function and saved as a new specification.
The global pattern parameters are the basis for the parameters in the Configuration / Configuration k&w dialog box and in the pattern parameter tables.

Configuration/k&w Configuration

Pattern parameter tables

Special machines and gauges require specific pattern parameters:

The function is not available when a pattern or module is open.
For a module, the parameters are also adopted from the global pattern parameters. However, these cannot be changed. However, you can add and edit your own entries.

Sequence with which the global pattern parameters are used in the pattern:

In case you created your own pattern parameters that differ from the Stoll templates, they will be used with the following priority.

  1. Machine specific private file
  2. Machine specific Stoll template
  3. Private default file
  4. Stoll default file

How to create your own global pattern parameters for a specific machine class and gauge:

  1. The new pattern or module must not yet exist.
    1
    Open the pattern parameter file with label for machine classification and gauge.
    Example: D:\ Stoll\ M1plus\ 4.x.xxx\ ConfigData\ GlobalParameters_752_E9.2.mdv
    2
    Run the Global Pattern Parameters... function in the Pattern Parameters menu.
  1. The Global Pattern Parameters dialog appears.
  2. 3
    Select the desired template under Stoll templates.
    4
    If necessary, transfer to a specific machine.
    Machine:
    5
    If necessary, limit to a specific gauge.
    Gauges:
    6
    Click on Generate new file.
  3. The new file appears in the right column.
    The file name contains the identification of the selected machine and gauge.
  4. 7
    Click on Open user-defined file.
  5. The GlobalParameters dialog box appears where you call up the following dialog boxes and pattern parameter tables:

Button

Target

Configuration section

 

Default

Config­uration

k&w

k&w configuration

_____________________________

Stitch length table

Stitch length table

Fabric take-down table

Fabric take-down table
Auxiliary Take-down Table

Carriage Speed Table

Carriage speed table

Racking Correction Table

Racking Correction Table

Sintral Functions

Sintral Functions

NPS Table

NPS Table

PNP Table

PNP Table

    8
    Call up the desired dialogs and pattern parameter tables.
    9
    Change the settings and save them in the corresponding dialog box.
  1. A new pattern or module for this machine and gauge will automatically be generated on the basis of the changed, private global pattern parameters.
  2. Your private global pattern parameters will be copied to the corresponding directories by the update to the new release.
    D:\ Stoll\ M1plus\<New version>\ConfigData\Private\...

How to display the global pattern parameters:

  1. No pattern or module may be open.
    1
    Run the Global Pattern Parameters... function in the Pattern Parameters menu.
  1. The Global Pattern Parameters dialog appears.
  2. 2
    Select the desired template under Stoll templates.
    3
    Click on Open Stoll template write protected.
  3. The GlobalParameters dialog box appears.
  4. 4
    Call up dialogs or pattern parameter tables.
  5. You can view the specified pattern parameters without creating new, private templates.
  6. 5
    Exit dialogs or pattern parameter tables with Cancel.