Parameters of the Sintral functions

Parameters of the Sintral functions in use:

The specifications for the yarn carriers, stitch length, fabric take-down and carriage speed are read out from the Sintral function in this section.

    1
    Select the Sintral function in the list of the Sintral Functions dialog box.
  1. In the Parameters sections appears the name of the selected Sintral function under Function and the data are displayed in the tabs.

The display is not available when no or several Sintral functions is/are selected.

Tabs:

Tab

Table column

Meaning

YC
(Yarn Carrier)

 

Exact designation of the yarn carriers regarding yarn and yarn carrier position.
If the Sintral function is used then the entries will be applied to the Yarn Field Allocation dialog box.
: The values can be edited.

YC rail

Specification of the yarn carrier rail.

YC type

Specification of yarn carrier type.
: The entries N (Normal), I (Intarsia) and Empty field (without type) are possible.

Yarn No.

Specification of yarn number.

Yarn type

Specification of the yarn type.

Position

Specification of the yarn carrier position in the home position YG.

NP
(Stitch Length)

 

Contains the specifications on the stitch length.
If the Sintral function is used then the entries will be applied to the stitch length table of the pattern.
: The values can not be edited.

NP index

Specification of the NP index.

Value

Specification of the stitch length

mm

Specification of the stitch length in millimeter.

PNP
(Reclaiming)

 

Reclaiming (Only with CMS 730 S und CMS 830 S)

PNP Index

Specification of the PNP index.

Value

Specification of the PNP value.

NPS
(Second stitch tension)

 

Second Stitch Tension (Only with CMS 730 S und CMS 830 S)

NPS-Index

Specification of the NPS index for the second stitch tension.

Value

Specification of the NPS value.

WMF
(Fabric Take-down)

 

Specifications for fabric take-down.
f the Sintral function is used then the entries will be applied to the Fabric Take-down table of the pattern.
: The entries in the tab cannot be edited.

WMF Index

Specification of the WMF index.
The fabric take-down values must be defined in the Fabric take-down table.

W+F
(Auxiliary take-down)

 

Specifications for the auxiliary take-down function.

: The entries in the tab cannot be edited.

W+F-Index

Specifications for the W+F function.

MSEC
(Carriage Speed)

 

Specifications on the carriage speed.
If the Sintral function is used then the entries will be applied to the Carriage Speed table of the pattern.
: The entries in the tab cannot be edited.

MSEC index

Specification of the MSEC index.

m/s

Specification of the speed value in meters/second.

RS
(Cycle counters)

 

Specifications for cycle counters

RS

Number of the cycle counter

Value

Value of the cycle counter

For Sintral functions of type Head, no information is read out and displayed, as this type is only used for comments.

Buttons:

Buttons

Function

Apply

Apply the modifications in the Yarn Carrier tab to the pattern.

Reset

Undo the modifications in the Yarn Carrier tab and replace them with the values previously present.

Reload

Reload the parameters from the Sintral function in the display.